| 1. IQC | 
| Main Responsibility:Spot-check the material dimension, ingredients and etc… based on standard inspection procedure in order to effectively reduce inferior parts into the manufacturing process.The qualified materials are then stamped with a mark “PASS” on the label and warehouse testing report. |  | 
| a. Dimension Measurement |  | 
| Utilizing Misutoyo caliper to measure the material including case, actuator, cover and so on.Misutoyo profile projector is for precision measurement
 | 
| b. Electro-plating coating thickness test |  | 
| Fischer X-Ray coating thickness gauge is to test the material and thickness of electro-plate coating.
 | 
| 2. IPQC | 
| Main Responsibility:Implement self-inspection and patrol inspection based on the standard operation procedure in order to prevent substandard parts from going to the next work station. |  | 
| a. Mold / Tool Adjustment |  | 
| The tools are regularly handed to our engineering division for precision measurement in order to avoid any accuracy alteration caused during the production process.
 | 
| 3. FQC | 
| Main Responsibility:Implement the inspection on the quality of finished products by using testing equipment in order to eliminate inferior products not judged by the outer appearance or caused by electric characteristic. |  | 
| a. Function Test and Contact Resistance Test |  | 
| Utilizing specialized testing tool to test if the function is normal.Utilizing digital miliohmmeter & comparator to test the contact resistance in order to effectively eliminate inferior products.
 | 
| 4. OQC | 
| Reponsibility:Spot-check each lot of products for quality before final shipment. We also have a destructive test on the operating life in order to minimize inferior products to be shipped to customers. |  | 
| a. Waterproof Test |  | 
| For sealed switches, we have bubble test by utilizing fluorocarbon 3M FC-40.
 | 
| b. Feeling Test |  | 
| Utilizing AICOH testing equipment to make feeling test for pushbutton switches.
 | 
| c. Mechanical Life & Electrical Life Test |  | 
| Utilizing endurance testing machine to test the operating life in rated current load.
 | 
| d. Environment Test |  | 
| Utilizing imported environment testing machine to test the resistance low temperature, resistance high temperature and resistance humidity.
 | 
| e. Insulation Resistance Test |  | 
| GW Instek multi-function testing facilities is to test the insulation resistance and dielectric strength.
 |